ChaRM - Document ID not created after change is approved
Hi, We are using Solution Manager 7.1 SPS 11 and have configured ChaRM.While testing we noticed that once the "Request for change" is approved by Change manager, document ID for corresponding "Normal...
View ArticleTextprotocoll in AI_CRM_IM_SHORT_TEXT_LINK_FORM
Hello, I would like to implement a part of a textprotocoll (Incident) in the Smartform AI_CRM_IM_SHORT_TEXT_LINK_FROM Why I would like to do it? When a Key-User create a Incident Message, he get...
View ArticleRule Policy: Find Partner
Hi, I build a Rule to find a Partner automatic. For example: The Reporter create a Incident and I would like that the Incident will automatically forward to Message Processor. How can I do it?
View ArticleManage CUA during Upgrade
HI We have CUA configured in Solution Manager .We are planning to upgrade solution manager to the latest patch available . During downtime of solution manager ,How do we manage the CUA and user...
View ArticleError when executing CBTA test script with External variant
hai I have created a test configuration using CBTA for tcode MM03. Test data container is created with external variant. i.e Text file contains VAR1 with values I have assigned this test data container...
View Article" System Monitoring, Most of the metric, In Performance Tab is Grey"
Hi All, Currently we are using SAP Solution Manager 7.1 SP8, I have configured System Monitoring, Under Technical Monitoring. After Configuration, When I check the results in WorkCentre, Most of the...
View ArticleHow to map the fields for post processors in customized keyfigure for BP...
Hi all, I am developing a customized key figure which is typical business specific, which is not availbale from the stanadard list of KPIs for anytics purpose in BP Monitoring. And for the same I am...
View ArticleError While Installaing Willy Introscope Enterprise Manager
Hi Experts, We are facing an error while Installing Willy Introscope Enterprise Manager. Please find the below screen for the error.. So i have downloaded manually libintl-8.dll and placed in...
View ArticleEmail Notifications via SolMan
Hello All, I have setup monitoring alerts for PI 7.4 system via SolMan.The alerts are basically notifications received via e-mails. The problem is even though the alerts are working fine, the message...
View ArticleNo Performance Data in Interactive Report of System Monitor
Hello, I have implemented Technical Systems monitoring in Solution Manager 7.1 SPS 12. Technical Monitoring is setup correctly and it give correct monitoring data for managed systems.Now Dialog...
View ArticleBPMon data not getting collected in 0SM_BPM
Hi Experts, Deatils -1. We are on Solution Manager 7.1 SPS10 - ST/710/00102. BPMon is configiured and BW data collections checkbox is also ticked. Cofiguration wise all seems OK but data is not...
View ArticleSystem Recommendation - list of implemented notes
Hello everyone,Tool System recommendation offer list of recommended notes which sould be implemented. But! Where can I find list of already implemented notes of satelite system?
View ArticleSUM execution error, Java does not start and looping in Solman 7.1 SP12
Hi, I am doing update Sp12 for Solution Manager 7.1 from SP10. In the Execution phase, I got error START-AS-JAVA error Of cause, I did all of correct SAP Kernel upgrade and tools also I did follow the...
View ArticleSOLUTION MANAGER ITMS :not able to see the incidents in solman
Hi All , I have done the configuration of ITSM in my Solman 7.1.now I am facing a issue while my end user login (solman) & run solman_workcenter to see their incidents but they are not able to see...
View ArticleSoftware Upgrade Manager (SUM) error in
Dear Experts, I am trying to upgrade my Solman from sp04 to sp12 during the step 2 I am facing following error my ASCS and SCS running I am able to login through http://hostname:50000/nw and also...
View ArticleCustom Code City Model “No SVG support”
Hello, In the SolMan workcenter Custom Code Management Overview screen the City Model says “No SVG Support”. I’ve tried it on different SP12 SolMan systems on different PC’s with different IE versions....
View ArticleDiagnostic Agent: JVM-Settings
Hello experts!After the installation of Diagnostic Agent on Windows Server this agent does not start.We found that we have a other old JDK using by other applications.Because we set the PATH...
View ArticleError in CA introscope step in solman-setup
Hi All, I am facing a problem in configuring CA introscope step in solman_setup we have entrprise manager upgraded and SMD agent is installed. When i gave the EM path and diagnostics agent, it fetched...
View ArticleUser Authorization Issue in ChaRM
Hi, We have implemented ChaRM in Solman 7.1 system. I am restricting user authorization in ChaRM CD by giving the exact authorization keys in Auth. Object 'B_USERSTAT'. In our workflow, the person who...
View ArticleWhats the diff btwn SAP CCC and SAP CCoE?
Hi, I have come across a terms SAP Customer Competence Center and wanted to know more about it (SAP CCC Certification). However I am not able to find any details on the SAP CCCC and whenever I search I...
View Article